EasyManua.ls Logo

Fujitsu PRIMERGY TX300 S7 - Replacing the System Board

Fujitsu PRIMERGY TX300 S7
962 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TX300 S7 / RX350 S7 Upgrade and Maintenance Manual 855
System board and components
Ê Close the side / top cover as described in section "Mounting the top cover"
on page 115 (rack server) or "Mounting the side cover" on page 122 (tower
server).
Ê When working on a rack-mounted server, secure it in the rack as described
in section "Sliding the server into the rack" on page 132.
If the server has been completely removed from the rack for maintenance
purposes, reinstall and secure it in the rack as described in section
"Mounting the server in the rack" on page 130.
Ê Reconnect the AC power cords to the power supply units and secure them
with PSU cable brackets as described in section "Connecting the server to
the mains" on page 133.
Ê If BitLocker functionality is used and has been disabled before starting the
maintenance task, re-enable BitLocker as described in section "Enabling
BitLocker functionality" on page 165.
14.5 Replacing the system board
Note on TPM
I The system board can be equipped with an optional TPM (Trusted
Platform Module). This module enables third party programs to store key
information (e. g. drive encryption using Windows Bitlocker Drive
Encryption).
If the customer is using TPM functionality, the TPM has to be removed
from the defective system board and connected to the new system
board. For a detailed description, please refer to section "Replacing the
TPM board" on page 844.
The TPM is activated in the system BIOS.
Field Replaceable Units (FRU)
Average hardware task duration: 50 minutes
Average software task duration: 10 minutes

Table of Contents

Other manuals for Fujitsu PRIMERGY TX300 S7

Related product manuals