686 Upgrade and Maintenance Manual TX300 S7 / RX350 S7
Accessible drives
Ê Close the side / top cover as described in section "Mounting the top cover"
on page 115 (rack server) or "Mounting the side cover" on page 122 (tower
server).
Ê When working on a rack-mounted server, secure it in the rack as described
in section "Sliding the server into the rack" on page 132.
If the server has been completely removed from the rack for maintenance
purposes, reinstall and secure it in the rack as described in section
"Mounting the server in the rack" on page 130.
Ê Reconnect the AC power cords to the power supply units and secure them
with PSU cable brackets as described in section "Connecting the server to
the mains" on page 133.
Ê Verify if your backup software solution requires additional configuration after
installing, removing or replacing an accessible drive as described in section
"Verifying and configuring the backup software solution" on page 155.
12.5 Slimline ODD and LSD in Multibay box
12.5.1 Installing the slimline ODD or LSD
12.5.1.1 Required tools
Preliminary and concluding steps: tool-less
Installing a slimline ODD or LSD:
Phillips PH2 / (+) No. 2 screw driver
Slotted screw driver (for bending in or out accessible drive mounting
brackets)
Upgrade and Repair Units (URU)
Average task duration: 10 minutes