348 Upgrade and Maintenance Manual TX300 S7 / RX350 S7
Hard disk drives / solid state drives
7.4.7.3 Removing the 4x 3.5-inch HDD extension box
Ê Unlock and pull the 4x 3.5-inch HDD extension box out of its installation bays
as described in section "Removing the 4x 3.5-inch HDD extension box" on
page 340.
7.4.7.4 Removing the slimline ODD from the defective HDD extension
box
Ê If applicable, remove the slimline ODD from the defective 4x 3.5-inch HDD
extension box as described in section "Removing the slimline ODD from the
extension box" on page 750.
7.4.7.5 Installing the slimline ODD and LSD module into the new HDD
extension box
Ê If applicable, reinstall the slimline ODD into the new 4x 3.5-inch HDD
extension box as described in section "Installing the slimline ODD into the
HDD extension box" on page 740.
7.4.7.6 Installing the 4x 3.5-inch HDD extension box
Ê Install the new 4x 3.5-inch HDD extension box as described in section
"Installing the 4x 3.5-inch HDD extension box" on page 330.
7.4.7.7 Concluding steps
Perform the following procedures to complete the task:
Ê Reinstall the system fan holder as described in section "Installing the system
fan holder" on page 390.
Ê Reinstall the air duct as described in section "Installing the system air duct"
on page 102.
Ê Close the front cover and reinstall the ID card as described in section
"Closing the server" on page 112.
Ê Reinstall all hard disk drives into their original slots in the HDD extension box
as described in section "Installing 3.5-inch HDD modules" on page 272.
Ê Close the side / top cover as described in section "Mounting the top cover"
on page 115 (rack server) or "Mounting the side cover" on page 122 (tower
server).