TX300 S7 / RX350 S7 Upgrade and Maintenance Manual 733
Accessible drives
Figure 515: Mounting the slimline ODD dummy insert in the installation frame
Ê Carefully bend out the LSD dummy cover plate (1) and fit its other edge into
the LSD slot (2).
12.6.2.6 Installing accessible drive dummy covers
I if the 2x 3.5-inch HDD extension box is to be reinstalled in the system,
the following description does not apply. Please proceed as described in
section "Installing the 2x 3.5-inch HDD extension box" on page 315.
Installing accessible drive filler covers
Ê Install accessible drive filler covers (C26361-K644-C933) into the empty
installation bays 2 and 3 as described in section "Installing accessible drive
dummy covers" on page 681.
V CAUTION!
Always replace filler covers into unused drive bays to comply with
applicable EMC regulations and satisfy cooling requirements.