TX300 S7 / RX350 S7 Upgrade and Maintenance Manual 75
Basic hardware procedures
4.4 Extending / removing the server from the
rack
I In most cases maintenance tasks can be performed while the server is
extended from the rack. However, depending on accessibility or security
guidelines, it may make sense to completely remove the server from the
rack cabinet for maintenance purposes.
V CAUTION!
Use the anti-tilt plate to prevent the rack from tipping when installing
the rack. Pulling the server out of the rack without having installed the
anti-tilt plate may cause the rack to tip over.
Be careful not to pinch fingers or clothes when sliding out the server
or pushing it back. Failure to do so may cause injury.
For further safety information, please refer to chapter "Important
information" on page 51.
4.4.1 Preliminary steps
Ê Shut down and power off the server as described in section "Shutting down
the server" on page 71.
Ê Remove the AC power cords from the PSU cable brackets and disconnect
them from the system as described in section "Disconnecting the server
from the mains" on page 72.
Ê Remove all remaining external cables from the rear connector panel and
expansion cards. For further information, refer to section "Connectors and
indicators" on page 948.