TX300 S7 / RX350 S7 Upgrade and Maintenance Manual 845
System board and components
14.3.3.1 Required tools
Preliminary and concluding steps: tool-less
Removing the system board:
Phillips PH2 / (+) No. 2 screw driver
Replacing the TPM:
Bit screw driver
TPM bit insert
(
*
)
thin slotted screw driver (2 x 0.4 mm)
(
*
)
(
*
)
For the Japanese market:
Dedicated TPM screw driver (CWZ8291A)
TPM module fixing tool (S26361-F3552-L909)
14.3.3.2 Preliminary steps
Before replacing the TPM board, perform the following steps:
Ê Disable BitLocker functionality as described in section "Disabling BitLocker
functionality" on page 141.
Ê Locate the desired server as described in section "Locating the defective
server" on page 64.
Ê Shut down the server as described in section "Shutting down the server" on
page 71.
Ê Remove the AC power cords from the PSU cable brackets and disconnect
them from the system as described in section "Disconnecting the server
from the mains" on page 72.
Ê When working on a rack-mounted server, extend it out of the rack as
described in section "Extending the server out of the rack" on page 76.
If further required, remove the server from the rack as described in section
"Removing the server from the rack" on page 77.
Ê Open the side / top cover as described in section "Removing the top cover"
on page 79 (rack server) or "Removing the side cover" on page 88 (tower
server).
Ê Remove the air duct as described in section "Removing the system air duct"
on page 100.