322 Upgrade and Maintenance Manual TX300 S7 / RX350 S7
Hard disk drives / solid state drives
Ê Pull out the ID card and open the front cover as described in section
"Opening the server" on page 79.
Ê Remove the air duct as described in section "Removing the system air duct"
on page 100.
Ê Remove the system fan holder as described in section "Removing the
system fan holder" on page 389.
7.4.3.3 Removing the 2x 3.5-inch HDD extension box
Figure 199: Opening the accessible drive locking bar
Ê Remove all cables from the 2x 3.5-inch HDD extension box backplane.
Ê If applicable, remove all cables from the slimline ODD.
Ê If applicable, remove the LSD cable from system board connector SMB 1.
Ê Press out on the locking latch to disengage the accessible drive locking bar
(1).
Ê Fold up the accessible drive locking bar (2).