756 Upgrade and Maintenance Manual TX300 S7 / RX350 S7
Accessible drives
Ê Shut down the server as described in section "Shutting down the server" on
page 71.
Ê Remove the AC power cords from the PSU cable brackets and disconnect
them from the system as described in section "Disconnecting the server
from the mains" on page 72.
Ê When working on a rack-mounted server, extend it out of the rack as
described in section "Extending the server out of the rack" on page 76.
If further required, remove the server from the rack as described in section
"Removing the server from the rack" on page 77.
Ê Open the side / top cover as described in section "Removing the top cover"
on page 79 (rack server) or "Removing the side cover" on page 88 (tower
server).
Ê Remove the air duct as described in section "Removing the system air duct"
on page 100.
Ê Remove the system fan holder as described in section "Removing the
system fan holder" on page 389.
I Removing the front cover is not required in order to replace the slimline
ODD or LSP in the 2x 3.5-inch HDD extension box.
12.7.3.3 Removing the 4x 3.5-inch HDD extension box
Ê Remove all cables from the 4x 3.5-inch HDD extension box backplane.
Ê Remove all cables from the slimline ODD.
Ê Remove the 4x 3.5-inch HDD extension box from the server as described in
section "Removing the 4x 3.5-inch HDD extension box" on page 341.
12.7.3.4 Removing the slimline ODD from the HDD extension box
Ê Remove the defective slimline ODD from the 4x 3.5-inch HDD extension box
as described in section "Removing the slimline ODD from the extension box"
on page 750.
12.7.3.5 Installing the slimline ODD into the HDD extension box
Ê Install the new the slimline ODD onto the 4x 3.5-inch HDD extension box as
described in section "Installing the slimline ODD into the HDD extension
box" on page 756.