TX300 S7 / RX350 S7 Upgrade and Maintenance Manual 65
Basic hardware procedures
4.1.2 Determining the error class
The Local Service Concept (LSC) allows you to identify defective server
components. Failure events are assigned to one of two error classes:
Global Error events that need to be resolved by maintenance personnel
Customer Self Service (CSS) error events that may be resolved by
operating personnel
Global Error and CSS LEDs indicate, if the defective component is a customer
replaceable unit or if maintenance personnel needs to be dispatched to replace
the part.
I The indicators also light up in standby mode and after a server restart
due to a power failure.
4.1.2.1 Global Error indicator
Figure 4: Global Error indicator on front panel
Ê Check the Global Error indicator on the front or connector panel of the
server:
Indicator Status Description
Global error
indicator
off no critical event (non CSS component)
orange on
prefailure detected (non CSS component),
requires (precautionary) service
intervention
orange
flashing
non CSS component failure or software /
agent related error, requires service
intervention