70 Upgrade and Maintenance Manual TX300 S7 / RX350 S7
Basic hardware procedures
I In addition to local diagnostic indicators, CSS or Global Error LEDs
indicate, if the defective component is a customer replaceable unit or if a
service technician needs to be dispatched to replace the part (see
section "Determining the error class" on page 65).
If the system has been powered off to replace a non hot-plug unit, a
system of PRIMERGY diagnostics indicators guides you to the faulty
component.
D PCI card
off PCI card operational
orange on PCI card failure
E CPUs
off CPUs operational
orange on CPU failure
F Memory
off memory module operational
orange on memory module failure
G
PSUs
green on PSUs operational
H orange on PSU failure
I Main power green on main voltages are within range
K Standby power yellow on standby voltages are within range
L iRMC
green
flashing
iRMC S3 management controller is
operational
M System fans
off fan running
orange on fan failure
N Battery orange on battery failure
Indicator Status Description