78 Upgrade and Maintenance Manual TX300 S7 / RX350 S7
Basic hardware procedures
Ê Shut down the server and remove external cables as described in section
"Preliminary steps" on page 75.
Ê Unlatch and pull the server out of the rack as described in section "Extending
the server out of the rack" on page 76.
Figure 13: Removing the server from the rack
Ê Release the locking bars on both rails (1).
Ê Lift up the front of the server as shown so that the front and middle rack
mounting bolts are disengaged from the mounting points on the telescopic
rails (2).
Ê Lift the server out of the rear mounting points (3) and place it on an even
surface.