952 Upgrade and Maintenance Manual TX300 S7 / RX350 S7
Appendix
Ê Remove the air duct as described in section "Removing the system air duct"
on page 100.
Ê Press the Indicate CSS button (1) to highlight defective components.
Component LEDs
I LEDs A, B and C are visible from the outside on the server rear. All other
LEDs are only visible if the server cover has been opened.
Indicator Status Description
A ID indicator blue on
server has been highlighted using
ServerView Operations Manager or the
ID button on the front panel for easy
identification
B
CSS
(Customer Self
Service)
off no critical event (CSS component)
yellow on prefailure detected (CSS component)
yellow
flashing
CSS component failure
C
GEL
(Global Error
LED)
off no critical event (non CSS component)
orange on
prefailure detected (non CSS
component)
orange
flashing
non CSS component failure
Possible reasons:
sensors report overheating
sensor is defective
–CPU error
software reports an error
D PCI card
off PCI card operational
orange on PCI card failure
E CPUs
off CPUs operational
orange on CPU failure
F Memory
off memory module operational
orange on memory module failure
G
PSUs
green on PSUs operational
H orange on PSU failure