[NETWORK SENSOR SETUP] section
The [NETWORK SENSOR SETUP] section allows you to set up compatible FURUNO
NMEA2000 sensors. Calibrations and offsets applied in this menu are also applied to
the sensor itself.
[CALIBRATION] section
[DATA DAMPING] section
[FUSION] section
[BROWSER INSTALLATION] section
Others menu items
Menu item Description Options (setting range)
[Heading] Offset heading data. -180.0 to +180.0°
[Speed Through
Water]
Calibrate speed data. Enter amount in percentage. -50 to +50%
[Wind Speed] Offset wind speed data. Enter amount in percentage. -50 to +50%
[Wind Angle] Offset wind angle data. -180.0 to +180.0°
[Sea Surface
Temperature]
Offset sea surface temperature data. -50 to +50°F
Menu item Description Options (setting range)
[COG & SOG] Set data damping time. The lower the set-
ting the faster the response to change.
0 to 59 seconds
[Heading]
[Speed Through Water]
[Wind Speed&Angle]
[Rate of Turn]
Menu item Description Options (setting range)
[Connect to Fu-
sion]
Connect to your Fusion equipment.
[Fusion Auto
Volume]
Set to [ON] to allow this unit to control the Fusion vol-
ume automatically.
[OFF], [ON]
[Minimum
Speed]
Set the minimum speed threshold. Exceeding this
speed activates volume auto control.
0 to 99 kn
[Maximum
Speed]
Set the maximum speed threshold. 0 to 99 kn
[Volume In-
crease]
Set the amount of extra volume to output. 10 to 50%
Menu item Description
[FAX-30 Browser] Show the Facsimile Receiver FAX-30 display.
[FA-30 Browser] Show the AIS Receiver FA-30 display.
[FA-50 Browser] Show the AIS Receiver FA-50 display.
Menu item Description Option (setting range)
[Chart Master Device] Set to [ON] to set this equipment as the chart
master ([OFF]: sub).
[OFF], [ON]
[System ID] The system ID for this device within the network.
[IP Address] IP address for this unit within the network.
[Synchronization Log] Synchronization log for this unit within the network.

Table of Contents

Other manuals for Furuno NavNet TZtouch3 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Furuno NavNet TZtouch3 Series and is the answer not in the manual?

Furuno NavNet TZtouch3 Series Specifications

General IconGeneral
BrandFuruno
ModelNavNet TZtouch3 Series
CategoryMonitor
LanguageEnglish

Related product manuals