EasyManuals Logo

Gemalto Cinterion EHS6 User Manual

Gemalto Cinterion EHS6
513 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #125 background imageLoading...
Page #125 background image
Cinterion
®
EHS6 AT Command Set
6.3 AT+CLCK
EHS6_ATC_V03.001 15/12/3
Confidential / Released
Page 125 of 513
0 Lock is inactive
1 Lock is active
Password string used to lock and to unlock a <facility>. Length and authority for passwords depend on the
<facility> in question and are therefore listed in the section on parameter <facility>. Passwords can be
modified with AT+CPWD.
Integer or sum of integers each representing a class of information, i.e. a bearer service, telecommunication ser-
vice or bearer service group as defined in 3GPP TS 22.004 [25].
1Voice
2 Class 2 ("data") comprises all those individual data classes between 16 and
128, that are supported both by the network and the MS. This means, a setting
made for class 2 applies to all individual data classes (if supported). In addition,
you can assign a different setting to a specific class. For example, you can acti-
vate Call Forwarding for all data classes, but deactivate it for data class 64,
"dedicated packet access".
4Fax
8SMS
16 Data circuit sync
32 Data circuit async
64 Dedicated packet access
128 Dedicated PAD access
1...[7]...255 Combination of some of the above classes.
For example, the default setting 7 represents the sum of the integers 1, 2 and
4 (voice, data and fax).
The value 255 covers all classes.
If parameter "class" is omitted, the default value 7 is used.
Note
•The AT+CLCK command offers the full range of <class> parameters according to the 3GPP Technical Spec-
ifications. However, when you attempt to use a service option which is not provisioned or not yet subscribed
to, the setting will not take effect regardless of the response returned.
The responses in these cases vary with the network (for example "OK", "Operation not allowed", "Operation
not supported" etc.). To make sure check the extended error response with AT+CEER and the lock status with
<mode>=2.
Examples
EXAMPLE 1
Lock USIM card (<facility>= "SC")
<status>
(num)
<password>
(str)
<class>
(num)
AT+CLCK="SC",1,"9999"
The "SC" parameter enables or disables the SIM PIN authentication
(PIN 1) when you power up the ME.
OK
USIM card locked. As a result, SIM PIN 1 must be entered to enable ME
to register to the network.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Gemalto Cinterion EHS6 and is the answer not in the manual?

Gemalto Cinterion EHS6 Specifications

General IconGeneral
BrandGemalto
ModelCinterion EHS6
CategoryControl Unit
LanguageEnglish

Related product manuals