EasyManuals Logo

Gemalto Cinterion EHS6 User Manual

Gemalto Cinterion EHS6
513 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #128 background imageLoading...
Page #128 background image
Cinterion
®
EHS6 AT Command Set
6.4 AT+CPWD
EHS6_ATC_V03.001 15/12/3
Confidential / Released
Page 128 of 513
Factory defined USIM locks:
Typical examples of factory set USIM locks are prepaid phones or network locks, used to restrict the operation
of a mobile to a specific provider or operator. The client should be aware that each of these lock types can only
be unlocked if the associated password is available. The locks can only be set by the manufacturer and need to
be agreed upon between the parties concerned, e.g. provider, operator, distributor etc. on the one side and the
manufacturer on the other side. For details contact your local dealer or Gemalto M2M GmbH.
“PN“ Network Personalisation
“PU“ Network subset Personalisation
“PP“ Service Provider Personalisation
“PC“ Corporate Personalisation
Supplementary Service Call Barring:
Supplementary Service "Call Barring" allows to specify conditions under which calls will be disallowed by the
network.
The availability of the Supplementary Services varies with the network. To benefit from call barring the client will
need to subscribe them, though a limited number of call barring types may be included in the basic tariff pack-
age.
<password length>: The Network Password needs to be supplied from the network provider or network oper-
ator. Usually there is one 4 digit password which applies to all call barring options. For details contact your pro-
vider.
“AO“ BAOC (Bar All Outgoing Calls)
“OI“ BOIC (Bar Outgoing International Calls)
“OX“ BOIC-exHC (Bar Outgoing International Calls except to Home Country)
“AI“ BAIC (Bar All Incoming Calls)
“IR“ BIC-Roam (Bar Incoming Calls when Roaming outside the home country)
“AB“ All Barring services
“AG“ All outGoing barring services
“AC“ All inComing barring services
4...16 Length of password. The range of permitted length for a password depends on
the associated <facility>. It is available from the test command response,
or in the description of parameter <facility>.
Password specified for the facility.
Parameter <old password> can be ignored if no old password was allocated to the facility.
New password. Mandatory, if <old password> was an unblocking key.
Note
When changing PIN2 (<facility>="P2") it is recommended to check the new state of PIN2 by using the
AT+CPIN2 command.
Examples
EXAMPLE 1
To change PIN2
<password length>
(num)
<old password>
(str)
<new password>
(str)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Gemalto Cinterion EHS6 and is the answer not in the manual?

Gemalto Cinterion EHS6 Specifications

General IconGeneral
BrandGemalto
ModelCinterion EHS6
CategoryControl Unit
LanguageEnglish

Related product manuals