EasyManuals Logo

Gemalto Cinterion EHS6 User Manual

Gemalto Cinterion EHS6
513 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #286 background imageLoading...
Page #286 background image
Cinterion
®
EHS6 AT Command Set
11.2 AT+CGANS
EHS6_ATC_V03.001 15/12/3
Confidential / Released
Page 286 of 513
with all other information found in the PDP context definition.
If no <cid> is given or if there is no matching context definition, EHS6 will attempt to activate the context
using the values for PDP type and address provided by the network. The other parameters will be set to their
default values (see AT+CGDCONT).
If activation is successful, data transfer will proceed.
After data transfer is complete, and the layer 2 protocol termination procedure has completed successfully,
the V.250 command state is reentered and EHS6 returns the final result code OK.
In the event of an erroneous termination or a failure to start up, the V.250 command state is re-entered and
EHS6 returns the final result code NO CARRIER, or if enabled, "+CME ERROR: <err>". Attach, activate and
other errors may be reported. It is also an error to issue the AT+CGANS command when there is no pending
network request.
The command can be used in both normal and modem compatibility modes.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Gemalto Cinterion EHS6 and is the answer not in the manual?

Gemalto Cinterion EHS6 Specifications

General IconGeneral
BrandGemalto
ModelCinterion EHS6
CategoryControl Unit
LanguageEnglish

Related product manuals