11.2 AT+CGANS
EHS6_ATC_V03.001 15/12/3
Confidential / Released
Page 286 of 513
with all other information found in the PDP context definition.
If no <cid> is given or if there is no matching context definition, EHS6 will attempt to activate the context
using the values for PDP type and address provided by the network. The other parameters will be set to their
default values (see AT+CGDCONT).
If activation is successful, data transfer will proceed.
After data transfer is complete, and the layer 2 protocol termination procedure has completed successfully,
the V.250 command state is reentered and EHS6 returns the final result code OK.
In the event of an erroneous termination or a failure to start up, the V.250 command state is re-entered and
EHS6 returns the final result code NO CARRIER, or if enabled, "+CME ERROR: <err>". Attach, activate and
other errors may be reported. It is also an error to issue the AT+CGANS command when there is no pending
network request.