EasyManua.ls Logo

Gemalto Cinterion EHS6 - Page 289

Gemalto Cinterion EHS6
513 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Cinterion
®
EHS6 AT Command Set
11.4 AT+CGAUTO
EHS6_ATC_V03.001 15/12/3
Confidential / Released
Page 289 of 513
When the AT+CGAUTO=1 command is received, the MT will attempt to perform a PS attach if it is not yet
attached. Failure will result in ERROR or, if enabled +CME ERROR being returned to the TE. Subsequently,
the MT announces a network request for PDP context activation by issuing the URC RING to the TE, followed
by the intermediate result code CONNECT. The MT then enters V.250 online data state and follows the same
procedure as it would after having received a +CGANS=1 with no <L2P> or <cid> values specified.
If a PS attach will be initiated by this command and the MT is not able to attach for more than 385 seconds
(timer T3310 expired), command returns with "ERROR" or "+CME ERROR: unknown", but MT is still trying
to attach and the requested automatic mode <n> is in use.
If a network request for PDP context activation is answered automatically and if another AT command is
issued at the same time on the same interface, then this AT command is not executed. Any response belongs
to the automatic context activation procedure. If the AT command which caused the collision was a circuit
switched data call, the CONNECT response does not belong to this data call but to the PS. This can be
detected if ATX is not set to 0. CS data call will issue CONNECT <text>, PS will issue CONNECT only.