Cinterion
®
EHS6 AT Command Set
14.1 AT^SSTA
EHS6_ATC_V03.001 15/12/3
Confidential / Released
Page 357 of 513
Parameter Description
ME Remote-SAT interface states
1 OFF
2IDLE
Setting becomes effective after restarting the ME.
0
(D)
GSM character set
Input of a character requests one byte, e.g. "Y".
1 UCS2
To display the 16 bit value of characters represented in UCS2 alphabet a 4 byte
string is required, e.g. "0059" is coding the character "Y". For details please
refer to ISO/IEC 10646.
Remote-SAT handling (i.e. AT+STKPRO URC and AT+STKTR sequence) is only usable via the channnel on
which the Explicit Response (ER) mode was activated.
To change the serial channel execute AT^SSTA=1 on the desired channel and perform a restart.
0 SAT is already used on another instance.
1 SAT may be started on this instance via the write version of this command.
SAT Terminal Profile according to 3GPP TS 11.14 [21], 3GPP TS 31.111 [22], ETSI TS 102 223 [23].
The profile tells the SIM Application which features (e.g. Proactive Commands) are supported by the SIM Appli-
cation Toolkit implementation of the ME.
PAC user timeout in seconds.
This parameter is not applicable.
SIM Application type.
This parameter shows the type of SIM application currently running.
0 (U)SIM not inserted
1 2G Application (SAT)
2 3G Application (USAT)
Select Remote-SAT activation mode.
Setting becomes effective after restarting the ME. Removing and inserting the SIM does not affect the activation
status.
0
(D)
Automatic Response (AR) mode.
All commands and responses are exchanged automatically between the ME
and the SIM application. This eliminates the need to enter any Remote-SAT
commands including the AT^SSTA command.
If AR mode is enabled the ME enters the OFF state (<state>=1) after restart.
<state>
(num)
<Alphabet>
(num)(NV)
<allowedInstance>
(num)
<SatProfile>
(str)
<userTOut>
(num)
<AppType>
(num)
<mode>
(num)(NV)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Gemalto Cinterion EHS6 and is the answer not in the manual?

Gemalto Cinterion EHS6 Specifications

General IconGeneral
BrandGemalto
ModelCinterion EHS6
CategoryControl Unit
LanguageEnglish

Related product manuals