EasyManuals Logo

Gemalto Cinterion EHS6 User Manual

Gemalto Cinterion EHS6
513 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #461 background imageLoading...
Page #461 background image
Cinterion
®
EHS6 AT Command Set
19.6 AT^SRADC
EHS6_ATC_V03.001 15/12/3
Confidential / Released
Page 461 of 513
EXAMPLE 3
Periodic measurement at high sample rate (250ms):
EXAMPLE 4
Handling of "^SRADC" URCs and AT command execution on the same interface:
AT^SRADC=1,250
Start periodic measurement on the ADC channel.
Samples are taken every 250ms. Every second a
URC "^SRADC" appears to report the measured volt-
age. The number of samples is 5.
^SRADC: 5,76,76,77,76,76
^SRADC: 5,76,76,75,76,76
^SRADC: 5,77,77,76,76,76
^SRADC: 5,76,76,75,76,76
AT^SRADC=0
OK
Stop the periodic measurement
AT^SRADC=1,250
Start periodic measurement mode on the ADC chan-
nel. Samples are taken every 250ms.
^SRADC: 5,76,76,77,76,76
^SRADC: 5,76,76,75,76,76
^SRADC: 5,77,77,76,76,76
^SRADC: 5,76,76,75,76,76
AT^SRADC?
Input of AT command and <CR> takes some sec-
onds.
^SRADC: 1,250
OK
^SRADC: 5,75,75,75,75,75
Some URCs were buffered during command input
and sent after completion.
^SRADC: 5,76,76,77,76,76
^SRADC: 5,76,76,75,76,76
^SRADC: 5,77,77,76,76,76
^SRADC: 5,76,76,75,76,76
^SRADC: 5,77,77,76,76,76
^SRADC: 5,76,76,77,76,77
^SRADC: 5,76,76,75,76,76

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Gemalto Cinterion EHS6 and is the answer not in the manual?

Gemalto Cinterion EHS6 Specifications

General IconGeneral
BrandGemalto
ModelCinterion EHS6
CategoryControl Unit
LanguageEnglish

Related product manuals