Configuration
7-345
L
EDSVS9332P-D22 EN 3.0
Code ImportantPossible settings
No. SelectionLenzeLCD
[C0688] → Selection list 1
CMP2
1 CMP2-IN1 1000 FIXED0%
Configuration - analog input signals
2 CMP2-IN2 1000 FIXED0%
C0689
0
-199.99 {0.01 %} 199.99
1 (C0688/1)
2 (C0688/2)
C0690 FUNCTION 1 1
2
3
4
5
6
IN1 = IN 2
IN 1 > IN2
IN 1 < IN2
|IN1| = |IN2|
|IN1| > |IN2|
|IN1| < |IN2|
CMP3
Function selection ( c ompares the inputs IN1
and IN2)
C0691 HYS TERESIS 1.00 0.00 {0.01 %} 100.00 CMP3
Hysteresis
C0692 WINDOW 1.00 0.00 {0.01 %} 100.00 CMP3
Window
[C0693] → Selection list 1
CMP3
1 CMP3-IN1 1000 FIXED0%
Configuration - analog input signals
2 CMP3-IN2 1000 FIXED0%
C0694
0
-199.99 {0.01 %} 199.99
1 (C0693/1)
2 (C0693/2)
[C0700] IN 19523 FCODE-472/3 → Selection list 1 ANEG1
Configuration - analog input signal
C0701 (C0700)
0
-199.99 {0.01 %} 199.99
[C0703] IN 1000 FIXED0% → Selection list 1 ANEG2
Configuration - analog input signal
C0704 (C0703)
0
-199.99 {0.01 %} 199.99
C0710 FUNCTION 0 0
1
2
Rising edge
Falling edge
Both edges
TRANS1
Function selection (edge evaluation)
C0711 PULSE T 0.001 0.001 {0.001 s} 60.000 TRANS1
Pulse time of TRANS1
[C0713] IN 1000 FIXED0 → Selection list 2 TRANS1
Configuration of digital input signal
C0714 (C0713)
0
C0715 FUNCTION 0 0
1
2
Rising edge
Falling edge
Both edges
TRANS2
Function selection (edge evaluation)
C0716 PULSE T 0.001 0.001 {0.001 s} 60.000 TRANS2
Pulse duration
[C0718] IN 1000 FIXED0 → Selection list 2 TRANS2
Configuration of digital input signal
C0719 (C0718)
0
C0720 FUNCTION 2 0
1
2
On delay
Off delay
On/Off delay
DIGDEL1
Function selection
C0721 DELAY T 1.000 0.001 {0.001 s} 60.000 DIGDEL1
Delay time
[C0723] IN 1000 FIXED0 → Selection list 2 DIGDEL1
Configuration of digital input signal
C0724 (C0723)
0
C0725 FUNCTION 2 0
1
2
On delay
Off delay
On/Off delay
DIGDEL2
Function selection
C0726 DELAY T 1.000 0.001 {0.001 s} 60.000 DIGDEL2
Delay time