Configuration
7-346
L
EDSVS9332P-D22 EN 3.0
Code ImportantPossible settings
No. SelectionLenzeLCD
[C0728] IN 1000 FIXED0 Selection list 2 DIGDEL2
Configuration of digital input signal
C0729 (C0728)
0
C0730 MODE 0 0
1
Start measurement
Stop measurement
OSZ
Start / Stop of the measured-value recording
C0731 STATUS 0
1
2
3
4
5
Measurement completed
Measurement active
Trigger detected
Cancel
Cancel after trigger
Read memory
OSZ
Current operating status
[C0732] Selection list 1
OSZ
1 CHANNEL1 1000 FIXED0%
Configuration - analog input signals
2 CHANNEL2 1000 FIXED0%
3 CHANNEL3 1000 FIXED0%
4 CHANNEL4 1000 FIXED0%
[C0733] Selection list 2
OSZ
T
r
i
g
g
e
r
i
n
p
u
t
1 DIG. TRIGGER 1000 FIXED0
T
r
i
gger
i
npu
t
Configuration of digital input signal
C0734 TRIG SOURCE 0 0
1
2
3
4
dig. trigger i nput
Channel 1
Channel 2
Channel 3
Channel 4
OSZ
Selection of trigger source
C0735 TRIGGER LEVEL 0 -32767 {1} 32767 OSZ
Setting trigger level for channel 1 ... 4
C0736 TRIGGER EDGE 0 0
1
LOW-HIGH edge
HIGH-LOW edge
OSZ
Selection of the trigger edge
C0737 TRIGGER DELAY 0.0 -100.0 {0.1 %} 999.99 OSZ
Setting of pre- and post-triggering
C0738 SAMPLING PERIOD 3 3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
1ms
2ms
5ms
10 ms
20 ms
50 ms
100 ms
200 ms
500 ms
1s
2s
5s
10 s
20 s
50 s
1min
2min
5min
10 min
OSZ
Selection of the sampling period
C0739 NUMBER OF
CHANNELS
4 1 {1} 4 OSZ
Number of channels to be measured
C0740 0 OSZ
1 START 0 0 {1} 16383 Defining the starting point for reading the data
memory. This makes a selective access to a
memory block possible
2 ENABLE/INHIBIT 0 0
1
Inhibit ”read data”
Enable ”read data”
Enable/inhibit
The data memory must be enabled for reading
Show/Hide Bookmarks