Configuration
7-347
L
EDSVS9332P-D22 EN 3.0
Code ImportantPossible settings
No. SelectionLenzeLCD
C0741 OSZ
1 VERSION OSZ
0
Version
2 MEMORY SIZE Memory size
3 DATA WIDTH Data width
4 NUMBER OF
CHANNELS
Number of channels
C0742 LENGTH OF DB
0
OSZ
Display of data block length
C0743 READ DB
0
OSZ
Reading an 8 byte data block
C0744 MEMORY SIZE 2048 0
1
2
3
4
5
6
512
1024
1536
2048
3072
4096
8192
OSZ
Adapt memory depth to the measuring task
C0749
0
OSZ
1 INDEX ABORT
Information on saving the measured values
2 NDEX TRIGGER
3 INDEX END
C0750 VP DENOM 16 1
2
4
8
16
34
64
128
256
512
1024
2048
4096
8192
16384
Vp = 1
Vp = 1/2
Vp = 1/4
Vp = 1/8
Vp = 1/16
Vp = 1/32
Vp = 1/64
Vp = 1/128
Vp = 1/256
Vp = 1/512
Vp = 1/1024
Vp = 1/2048
Vp = 1/4096
Vp = 1/8192
Vp = 1/16384
DFRFG1
Denominator - position controller gain
C0751 DFRFG1 TIR 1.000 0.000 {0.001 s} 999.900 DFRFG1
Tir (acceleration time)
C0752 MAX SPEED 3000 1 {1 rpm} 16000 DFRFG1
max. speed (here: maximum make-up speed)
C0753 DFRFG1 QSP 0.000 0.000 {0.001 s} 999.900 DFRFG1
Deceleration time when deceleration ramp is
activated
C0754 PH ERROR 2
.
10
9
10 {1} 2
.
10
9
DFRFG1
Following error
•
1 revolution = 65535 inc
C0755 SYN WINDOW 100 0 {1 inc} 65535 DFRFG1
Synchronisation window
C0756 OFFSET 0 -1
.
10
9
{1 inc} 1
.
10
9
DFRFG1
Offset
C0757 FUNCTION 0 0
1
No TP start
With TP start
DFRFG1
Function selection
[C0758] IN 1000 FIXEDPHI-0 → Selection list 4 DFRFG1
Input signal configuration
[C0759] QSP 1000 FIXED0 → Selection list 2 DFRFG1
Triggeri ng QSP
[C0760] STOP 1000 FIXED0 → Selection list 2 DFRFG1
Ramp function generator stop