Configuration
7-352
L
EDSVS9332P-D22 EN 3.0
Code ImportantPossible settings
No. SelectionLenzeLCD
C0852 TYPE OUT.W2 0 0
1
2
3
Analog signal
Digital 0-15
LOW phase
HIGH phase
AIF-OUT
Configuration - process output word 2 for
automation interface AIF (X1)
C0853 TYPE OUT.W3 0 0
1
2
Analog signal
Digital 16-31
HIGH phase
AIF-OUT
Configuration - process output word 3 for
automation interface AIF (X1)
C0854 TYPE OUT.W1 0 0
3
Analog signal
D2: LOW phase
AIF-OUT
Configuration - process output word 1 for
automation interface AIF (X1)
C0855
0
AIF-IN
Process input words hexadecimal for
automation interface X1
1 IN (0-15) Bit 00 {1} Bit 15 AIF-IN
2 IN (16-31) Bit 16 {1} Bit 31 AIF-IN
C0856
0
-199.99 {0.01 %} 199.99
AIF-IN
1 IN.W1
Decimal proc ess input words
2 IN.W2
Display: 100 % = 16384
3 IN.W3
C0857 IN.D1
0
-2147483648 {1} 2147483647 AIF-IN
32-bit phase information
C0858
0
-199.99 {0.01 %} 199.99
AIF-OUT
1 OUT.W1
Process output words
2 OUT.W2
Display: 100 % = 16384
3 OUT.W3
C0859 OUT.D1
0
-2147483648 {1} 2147483647 AIF-OUT
32-bit phase information
[C0860] → Selection list 1
CANx-OUT
1 OUT1.W1 5001
Configuration - process output words
2 OUT1.W2 1000 FIXED0%
3 OUT1.W3 1000 FIXED0%
4 OUT2.W1 1000 FIXED0%
5 OUT2.W2 1000 FIXED0%
6 OUT2.W3 1000 FIXED0%
7 OUT2.W4 1000 FIXED0%
8 OUT3.W1 1000 FIXED0%
9 OUT3.W2 1000 FIXED0%
10 OUT3.W3 1000 FIXED0%
11 OUT3.W4 1000 FIXED0%
[C0861] → Selection list 3
CANxOUT
1 OUT1.D1 1000 FIXED0INC
Configuration - 32-bit phase information
2 OUT2.D1 1000 FIXED0INC
3 OUT3.D1 1000 FIXED0INC
C0863
0
0 1
CANx-IN
1 IN1 (0-15)
Hexadecimal proce ss input words
2 IN1 (16-31)
3 IN2 (0-15)
4 IN2 (16-31)
5 IN3 (0-15)
6 IN3 (16-31)
C0864
0 Analog signal CANx-OUT
1 TYPEOUT1.W2 0
1
digital 0-15
Configuration - process output words
2 TYPEOUT2.W1 0
2 LOW phase
3 TYPEOUT3.W1 0