Installation
4-16
L
EDSVS9332P-B EN 3.0
4.2.7.2 Motor connection
Types 9321 ... 9326
Stop!
Always mount the PE connection and the shield sheet in the described order. The
corresponding parts can be found in the assembly kit.
Do not use the clips for strain relief.
9300STD011
UVW
PE
U
V
W
T1T2
289 0
;
:
1
2
3
4
5
6
7
M6
M5
0
Fig. 4-9 Proposal for motor connection
PE threaded bolt
Screw on M5 nut and tighten hand-tight
Fit fixing bracket for shield sheet
Fit serrated lock washer
Fit PE cable with ring cable lug
Fit washer
Fit toothed lock washer
Screw on M5 nut and tighten with 3.4 Nm (30 lb-in)
Use two M4 screws to screw shield sheet onto fixing bracket.
!
Clamp motor cable shield and cable shield for motor temperature monitoring with clip.
The shielding of the motor cable is only required to comply with existing standards (e. g. VDE 0160, EN50178, EN61800-3).
"
Connect motor cable to screw terminals U, V, W.
Observe c orrect pole co nnection and maximum motor cabl e length.
#
Connect cable for motor temperature monitoring to screw terminals T1 and T2.
Tip!
For an improved shield connection, additionally connect the shield to the PE threaded bolt.