Gocator 2300 & 2880 Series
Gocator Web Interface • Models and Part Matching • 126
Edge points along top of model removed.
Part is accepted. (Min set to 85%.)
Removing edge points does not cause the edge detection algorithm to run again.
To change model senstivity:
1. In the Models list, select the model you want to configure by clicking on its selection control.
2. Click the Model Editing tab.
3. Adjust the Model Sensitivity slider to exclude noise and to properly detect the distinguishing features that
will match parts.
You can also set the sensitivity value manually in the provided text box.
4. Save the job by clicking the Save button .