Gocator 2300 & 2880 Series
Gocator Web Interface • Measurement • 191
Measurement Illustration
Angle
Determines the angle (rotation) around the normal of
the alignment plane.
Parameter Description
Type Rounded Slot, Rectangle.
Nominal Width Nominal width of the opening.
Nominal length Nominal length of the opening.
Nominal Angle Nominal angle of the opening. The default orientation is the length of the opening
along the X axis.
The diagram above illustrates the case where the surface is not tilted. When the
surface is tilted, the orientation is defined with respect to the normal of the surface,
not with respect to the X-Y plane
Nominal Radius Nominal radius of the opening ends. If the opening type is set to rectangular, the
radius setting is disabled. The opening has an oval shape if the radius is equal to ½ of
the width. The opening is a rounded rectangle when the radius is less than ½ of the
width.