E-138
FX Series PLC User's Manual - Data Communication Edition
Inverter Communication
12 Related Data
12.5 FREQROL Inverter Parameter List
161
Frequency setting/key lock
operation selection
161
Frequency setting/key lock
operation selection
161
Frequency setting/key lock
operation selection
Automatic
restart
functions
162
Automatic restart after
instantaneous power failure
selection
162
Automatic restart after
instantaneous power failure
selection
162
Automatic restart after
instantaneous power failure
selection
163 First cushion time for restart 163 First cushion time for restart
−−
164 First cushion voltage for restart 164 First cushion voltage for restart
165
Stall prevention operation level
for restart
165
Stall prevention operation level
for restart
165
Stall prevention operation level
for restart
Current
detection
166
Output current detection signal
retention time
166
Output current detection signal
retention time
−−
167
Output current detection
operation selection
167
Output current detection
operation selection
Cumulative
monitor clear
170 Cumulative power meter clear 170 Watt-hour meter clear 170 Watt-hour meter clear
171 Operation hour meter clear 171 Operation hour meter clear 171 Operation hour meter clear
User group
172
User group registered display/
batch clear
172
User group registered display/
batch clear
172
User group registered display/
batch clear
173 User group registration 173 User group registration 173 User group registration
174 User group clear 174 User group clear 174 User group clear
Input terminal
function
assignment
178 STF terminal function selection 178 STF terminal function selection 178 STF terminal function selection
179 STR terminal function selection 179 STR terminal function selection 179 STR terminal function selection
180 RL terminal function selection 180 RL terminal function selection 180 RL terminal function selection
181 RM terminal function selection 181 RM terminal function selection 181 RM terminal function selection
182 RH terminal function selection 182 RH terminal function selection 182 RH terminal function selection
183 RT terminal function selection 183 RT terminal function selection 183 MRS terminal function selection
184 AU terminal function selection 184 AU terminal function selection 184 RES terminal function selection
185 JOG terminal function selection 185 JOG terminal function selection
--
186 CS terminal function selection 186 CS terminal function selection
187 MRS terminal function selection 187 MRS terminal function selection
188 STOP terminal function selection 188 STOP terminal function selection
189 RES terminal function selection 189 RES terminal function selection
Output
terminal
function
assignment
190 RUN terminal function selection 190 RUN terminal function selection 190 RUN terminal function selection
191 SU terminal function selection 191 SU terminal function selection 191 FU terminal function selection
192 IPF terminal function selection 192 IPF terminal function selection 192 A,B,C terminal function selection
193 OL terminal function selection 193 OL terminal function selection
−−
194 FU terminal function selection 194 FU terminal function selection
195 ABC1 terminal function selection 195 ABC1 terminal function selection
196 ABC2 terminal function selection 196 ABC2 terminal function selection
Multispeed
setting
232 Multi
speed setting (speeds 8) 232 Multi-speed setting (speed 8) 232 Multi-speed setting (speed 8)
233 Multispeed setting (speeds 9) 233 Multi-speed setting (speed 9) 233 Multi-speed setting (speed 9)
234 Multispeed setting (speeds 10) 234 Multi-speed setting (speed 10) 234 Multi-speed setting (speed 10)
235 Multispeed setting (speeds 11) 235 Multi-speed setting (speed 11) 235 Multi-speed setting (speed 11)
236 Multispeed setting (speeds 12) 236 Multi-speed setting (speed 12) 236 Multi-speed setting (speed 12)
237 Multispeed setting (speeds 13) 237 Multi-speed setting (speed 13) 237 Multi-speed setting (speed 13)
Multispeed
setting
238 Multispeed setting (speeds 14) 238 Multi-speed setting (speed 14) 238 Multi-speed setting (speed 14)
239 Multispeed setting (speeds 15) 239 Multi-speed setting (speed 15) 239 Multi-speed setting (speed 15)
240 SoftPWM operation selection 240 Soft-PWM operation selection 240 Soft-PWM operation selection
241
Analog input display unit
switchover
241
Analog input display unit
switchover
241
Analog input display unit
switchover
242
Terminal 1 added compensation
amount (terminal 2)
242
Terminal 1 added compensation
amount (terminal 2)
−−
243
Terminal 1 added compensation
amount (terminal 4)
243
Terminal 1 added compensation
amount (terminal 4)
FREQROL F700 Series FREQROL A700 Series FREQROL E700 Series
Function
Pr
No.
Name Pr No. Name
Pr
No.
Name

Table of Contents