EasyManua.ls Logo

Mitsubishi FX3U-232-BD

Mitsubishi FX3U-232-BD
668 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
E-142
FX Series PLC User's Manual - Data Communication Edition
Inverter Communication
12 Related Data
12.5 FREQROL Inverter Parameter List
LONWORKS
387 Initial communication delay time
−−
388 Send time interval at heart beat
389
Minimum sending time at heart
beat
390 % setting reference frequency
391
Receive time interval at heart
beat
392 Event driven detection width
Second
motor con-
stants
−−
450 Second applied motor 450 Second applied motor
451
Second motor control method
selection
−−
453 Second motor capacity
454 Number of second motor poles
455 Second motor excitation current
456 Rated second motor voltage
457 Rated second motor frequency
458 Second motor constant (R1)
459 Second motor constant (R2)
460 Second motor constant (L1)
461 Second motor constant (L2)
462 Second motor constant (X)
463
Second motor auto tuning
setting/status
Remote
output
495 Remote output selection 495 Remote output selection 495 Remote output selection
496 Remote output data 1 496 Remote output data 1 496 Remote output data 1
497 Remote output data 2 497 Remote output data 2 497 Remote output data 2
Communica-
tion error
500
Communication error execution
waiting time
−−
500
Communication error execution
waiting time
501
Communication error occurrence
count display
501
Communication error occurrence
count display
502
Stop mode selection at
communication error
502
Stop mode selection at
communication error
Maintenance
503 Maintenance timer 503 Maintenance timer 503 Maintenance timer
504
Maintenance timer alarm output
set time
504
Maintenance timer alarm output
set time
504
Maintenance timer alarm output
set time
S-pattern
acceleration/
deceleration
D
−−
516
S-pattern time at a start of
acceleration
−−
517
S-pattern time at a completion of
acceleration
518
S-pattern time at a start of
deceleraiton
519
S-pattern time at a completion of
deceleraiton
CCLink
−−
541
Frequency command sign
selection (CC-Link)
542
Communication station number
(CCLink)
542
Communication station number
(CCLink)
543 Baud rate (CCLink) 543 Baud rate selection (CC-Link)
544 CCLink extended setting 544 CC-Link extended setting
USB −−
547
USB communication station
number
547
USB communication station
number
548
USB communication check time
interval
548
USB communication check time
interval
FREQROL F700 Series FREQROL A700 Series FREQROL E700 Series
Function
Pr
No.
Name Pr No. Name
Pr
No.
Name

Table of Contents

Related product manuals