EasyManua.ls Logo

Omron F3SG-SRB Series - Page 115

Omron F3SG-SRB Series
399 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
87
F3SG-SR
User’s Manual
Chapter2 Override
System Operation and Functions
E
Factory default setting
Basic wiring diagram
External Device Monitoring used and in Manual Reset mode
External Device Monitoring not used and in Manual Reset mode
Variable Variable name Value Description
T1 Override input time limit 1 s Maximum input time of override input.
T2 Override time limit 600 s The duration time of the Override function. The OVERRIDE state
is cancelled if it continues for longer than this time limit.
+24 VDC
PNP
S1: Lockout or interlock reset switch or override switch
S2: Override cancel switch
S3, S4: Muting sensor
KM1, KM2: External device
*1. Also used as Override input line.
*2. Make sure to connect an override cancel switch to the RESET line when using the Override function.
Otherwise the OVERRIDE state may not be released by the override cancel switch, resulting in serious injury.
S3
S4
0V
S1
KM1
KM2
S2
0V
NPN
S3
S4
+24 VDC
S1
KM1
KM2
S2
*2
24V/0V (Brown)
MUTE B/
COM(-) (Pink)
MUTE A/PRE-RESET/
PSDI/COM(+) (Gray)
RESET/EDM (Yellow) *1
0V/24V (Blue)
F3SG-SR
receiver
24V/0V (Brown)
MUTE B/
COM(-) (Pink)
MUTE A/PRE-RESET/
PSDI/COM(+) (Gray)
RESET/EDM (Yellow) *1
0V/24V (Blue)
F3SG-SR
receiver
+24 VDC
PNP
S1: Lockout/interlock reset switch or override switch or override cancel switch
S3, S4: Muting sensor
*1. Also used as Override input line.
S3
S4
0V
S1
0V
NPN
S3
S4
+24 VDC
S1
F3SG-SR
receiver
24V/0V (Brown)
MUTE B/
COM(-) (Pink)
MUTE A/PRE-RESET/
PSDI/COM(+) (Gray)
RESET/EDM (Yellow) *
0V/24V (Blue)
F3SG-SR
receiver
24V/0V (Brown)
MUTE B/
COM(-) (Pink)
MUTE A/PRE-RESET/
PSDI/COM(+) (Gray)
RESET/EDM (Yellow) *
0V/24V (Blue)

Table of Contents

Related product manuals