111
F3SG-SR
User’s Manual
Chapter2 Operating Range Selection
System Operation and Functions
E
2-20-2. Factory Default Setting
The Operating Range Selection is configured as Long Mode. The operating range for the long mode
setting is from 0.3 to 20 m for F3SG-SR 25-mm/45-mm/85-mm detection capability model and from 0.3
m to 10 m for F3SG-SR 14-mm detection capability model.
2-20-3. Setting with Intelligent Tap
The user can select the mode of Operating Range Selection by the DIP Switch.
Make sure the Position 2 of the DIP Switch is set at ON (DIP Switch Enabled) to activate the settings by the DIP Switch.
Refer to Chapter 3 Setting with Intelligent Tap for more information on setting this function by the Intelligent Tap.
2-20-4. Setting with SD Manager 3
The user can make changes to the settings of this function by the SD Manager 3.
It is recommended that the Position 2 of the DIP Switch be set at OFF (DIP Switch Disabled).
Refer to Chapter 4 Setting with SD Manager 3 for more information on changing functions by SD Manager 3.
Function name Description Initial value Configurable value or numerical range
Operating Range Selection Select the operating range. Long mode Short mode/Long mode