305
F3SG-SR
User’s Manual
Chapter5 Wiring
Wiring and Installation
E
5-4-3-12. Easy Wiring Connector System with Reset Switch Connector
When arranging reset switch near F3SG-SR, easy wiring can be achieved by using a Reset Switch
Connector (F39-GCNY3, sold separately).
When using the Reset Switch Connector, the External Device Monitoring (EDM) cannot be used.
Reset Switch Connector (F39-GCNY3, sold separately)
Model Length
F39-GCNY3 0.5 m
(Unit: mm)
Material: PBT (Main body)
CN1
CN3
To receiver
CN2
To control panel
side
To reset switch
side
Plug marked with (blue circle): Connect to control panel side
Plug marked with (open circle): Connect to reset switch side
17.6 45.5
4.6 dia.
35.0
15.0
40.7
500
M12 IP67 connector, 8-wire
Insulated vinyl round cable, dia. 6
minimum bending radius R36
M12 IP67 connector, 4-wire
M12 IP67 connector, 8-wire
1RESET/EDM
24V/0V
MUTE A/PRE-RESET/PSDI/COM(+)
MUTE B/COM(-)
OSSD 1
OSSD 2
0V/24V
AUX
2
3
4
5
6
7
8
24V/0V
RESET/EDM
0V/24V
AUX
5
8
4
3
2
1
7
6
5
8
6
7
1
2
3
4
1
2
3
4
5
6
7
8
FemaleMale
Connected to Extended Socket-Straight Cable or
Extended Plug-Socket Cable of receiver
<Internal wiring diagram>
Connected to reset switch (NC contact)
Connected to root cable or Extended
Plug-Socket Cable of receiver
1
2
3
4
3
21
4
Male