Chapter2 Self-Test
F3SG-SR
User’s Manual
System Operation and Functions
2-5. Self-Test
2-5-1. Overview
The F3SG-SR performs the Self-Test when power is turned ON (within 3 s) to check for errors.
Also, it regularly performs the Self-Test (within a response time) while operating.
This function cannot be cancelled.
If an error is found in the Self-Test, the F3SG-SR enters the LOCKOUT state, keeps the safety outputs
in the OFF state, and indicates the error at the same time.
2-5-1-1. Self-Test details
The Self-Test detects such error as described below.
Emitter
Failure of emitter unit or circuit
CPU failure
Memory failure
Failure of DIP Switch
Receiver
Abnormal external power supply voltage
Failure of internal power supply circuit
Failure of receiver unit or detection circuit
CPU failure
Memory failure
Failure of safety output circuit
Disconnected or short-circuited cable
Failure of DIP Switch
Failure of End Cap
F3SG-SRA
F3SG-SRB
Subsequently performs periodic test
Power supply
ON
OFF
Self-Test
ON
OFF
3 s max.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron F3SG-SRB Series and is the answer not in the manual?

Omron F3SG-SRB Series Specifications

General IconGeneral
BrandOmron
ModelF3SG-SRB Series
CategorySecurity Sensors
LanguageEnglish

Related product manuals