133
F3SG-SR
User’s Manual
Chapter3 LED Indicators on Intelligent Tap
Setting with Intelligent Tap
E
3-4. LED Indicators on Intelligent Tap
Shown below are indication statuses of LED indicators on the Intelligent Tap when you purchased.
*1. When the safety outputs of the F3SG-SR are in the ON state, the outputs of the Intelligent Tap are in the ON state.
*2. When the safety outputs of the F3SG-SR are in the OFF state, the outputs of the Intelligent Tap are in the OFF state.
In the SETTING state to make settings with the SD Manager 3, the IN and OUT indicators blink.
(IN: Yellow, OUT: Green)
For more information on the statuses of the LED indicators in the SETTING state, refer to 4-1-4. SETTING State
of F3SG-SR with SD Manager 3 Connected.
Location Indicator Name Color Illuminated Blinking
1 IN Sensor status Yellow
Safety outputs of the F3SG-SR are
in the ON state
The F3SG-SR is in the LOCKOUT
state. Or the Intelligent Tap is
waiting for Push Switch operation (in
the Backup) or the Intelligent Tap
and F3SG-SR are waiting for restart
(in the Backup). Or communication
error in the Backup or between the
F3SG-SR and the Intelligent Tap. Or
the Restoration failed
2 OUT Output status
Green
Outputs of the Intelligent Tap are in
the ON state (*1)
The Restoration failed.
Or in the Restoration, the Intelligent
Tap has communication error, is
waiting for Push Switch operation or
transferring data, or the Intelligent
Tap and F3SG-SR are waiting for
restart
Red
Outputs of the Intelligent Tap are in
the OFF state (*2)
Communication error between the
F3SG-SR and the Intelligent Tap
3 IO-Link IO-Link Green -
Intelligent Tap communicates with
IO-Link Master. Or IO-Link circuit
error
4 ERR Lockout Red
The Intelligent Tap is in the
LOCKOUT state, or has
communication error, DIP Switch
circuit error at startup,
communication error in the Backup
or Restoration, restoration failure,
IO-Link circuit error, power supply
voltage error or other errors
-
4
3
2
1