214
Chapter4 Changing Settings with SD Manager 3
F3SG-SR
User’s Manual
Setting with SD Manager 3
4-3-4-6. Warning Zone
First, carry out 4-3-1. Preparing to Change Settings.
Next, click the icon below on the Top page.
The setting screen below is displayed.
For more information on warning zone, refer to 2-18. Warning Zone.
If using this function together with other functions, make settings taking the condition of adjacent zones into account.
For more information on zone adjacency conditions, refer to 2-19. Setting Zone Adjacency Conditions.
When changing the settings is complete, confirm the settings and write the configuration to the F3SG-SR.
To enable the written configuration, refer to 4-2-7-3. Writing Configuration into Intelligent Tap.
When connecting the Intelligent Tap to a F3SG-SR and trying to return the F3SG-SR to [Detecting], follow step 4 of
4-1-3-2. Connection Procedure When Using USB Connector to restart the F3SG-SR and Intelligent Tap, or click the
[Monitor] button.
No. Function name Description Initial value
Configurable value or
numerical range
1 Warning Zone Select Enable or Disable for the Warning Zone function.
When you want to restore the readout settings received from
the F3SG-SR, click [Recover status at readout].
Disable Disable/Enable from
upper/Enable from
lower
2 Setting by Select either manual setup using SD Manager 3 or setup by
teach-in.
Manual Manual/Teach-in
3 Zone setting
To configure zone settings, specify desired bottom and top
beam numbers from the drop-down list, or directly on the
chart. When you check the [Designate from chart] box, you
can specify a zone range by dragging red lines shown on the
chart. In both cases above, execute [Confirm zone] to confirm
the settings.
- Desired beam (in 1-
beam increments)
4 Confirm zone Confirm the settings of the zone. - -