192
Chapter4 Changing Settings with SD Manager 3
F3SG-SR
User’s Manual
Setting with SD Manager 3
When changing the settings is complete, confirm the settings and write the configuration to the F3SG-SR.
To enable the written configuration, refer to 4-2-7-3. Writing Configuration into Intelligent Tap.
When connecting the Intelligent Tap to a F3SG-SR and trying to return the F3SG-SR to [Detecting], follow step 4 of
4-1-3-2. Connection Procedure When Using USB Connector to restart the F3SG-SR and Intelligent Tap, or click the
[Monitor] button.
4-3-2-2. Reset Input Time
First, carry out 4-3-1. Preparing to Change Settings.
Next, on the Top page, click the icon below.
The setting screen below is displayed.
• For more information on manual reset, refer to 2-8. Interlock.
• For more information on pre-reset, refer to 2-9. Pre-Reset.
• For more information on PSDI, refer to 2-10. PSDI.
When changing the settings is complete, confirm the settings and write the configuration to the F3SG-SR.
To enable the written configuration, refer to 4-2-7-3. Writing Configuration into Intelligent Tap.
When connecting the Intelligent Tap to a F3SG-SR and trying to return the F3SG-SR to [Detecting], follow step 4 of
4-1-3-2. Connection Procedure When Using USB Connector to restart the F3SG-SR and Intelligent Tap, or click the
[Monitor] button.
No. Function name Description
Initial
value
Configurable value
or numerical range
1 Minimum pressing
time of reset switch
When using the manual reset function, set the minimum
pressing time of reset switch.
When using the pre-reset function, set the minimum pressing
time of the reset switch and pre-reset switch. The same value
is set on the pressing time of the reset switch and pre-reset
switch.
When using the PSDI function, set the minimum pressing time
of the reset switch.
100 ms 100 to 500 ms
(in 100 ms
increments)