200
Chapter4 Changing Settings with SD Manager 3
F3SG-SR
User’s Manual
Setting with SD Manager 3
4-3-3-3. Area Beam Indicator (ABI)
First, carry out 4-3-1. Preparing to Change Settings.
Next, on the Top page, click the icon below.
The setting screen below is displayed.
No. Function name Description Initial value Configurable value or numerical range
1 Output
operation mode
of ABI
Select the operation mode of the area
beam indicator (ABI).
Items 2 to 4 below can be set only
when [Output Information] is
selected.
Block/Unblock
Information
Disable/Block/Unblock Information/
Input signal linkage/Output information
2 Output
operation mode
of ABI
Select the information/signal
output by ABI.
Red
Safety output
information
For the information assigned to
ABI, refer to Information (Output
operation mode) assigned to Auxiliary
output of 4-3-3-1. Auxiliary Output.
Orange
Stable-state
information
Green
Safety output
information
3 Inverted signal
output of ABI
pattern
Select Enable or Disable for the
inverted setting of ABI patterns.
Red Enable Enable/Disable
Orange Enable
Green Disable
4 ABI output
pattern
Select an ABI output pattern. Red Solid-ON Illuminate/ON once/ON twice/ON three
times
Orange ON 1 time
Green Solid-ON

Table of Contents