198
Chapter4 Changing Settings with SD Manager 3
F3SG-SR
User’s Manual
Setting with SD Manager 3
Click the [Zone Setting] button to configure the designated beam output.
Zone setting is possible for desired channel and beam (in 1-beam increments). The settings after the zone is determined
are displayed in the zone information area under the chart.
For more information on designated beam output, refer to 2-23. Designated Beam Output.
When changing the settings is complete, confirm the settings and write the configuration to the F3SG-SR.
To enable the written configuration, refer to 4-2-7-3. Writing Configuration into Intelligent Tap.
When connecting the Intelligent Tap to a F3SG-SR and trying to return the F3SG-SR to [Detecting], follow step 4 of
4-1-3-2. Connection Procedure When Using USB Connector to restart the F3SG-SR and Intelligent Tap, or click the
[Monitor] button.
No. Function name Description Initial value Configurable item
1 Designated Beam
Output
Select Enable or Disable for the Designated Beam
Output function.
When you want to restore the settings received from
the F3SG, execute [Recover status at readout].
Disable Enable/Disable
2 Setting by Select manual setting using this software or setting by
teach-in.
Manual Manual/Teach-in
3 Zone setting Select a desired zone number. To configure zone
settings, specify desired bottom and top beam
numbers from the drop-down list, or directly on the
chart. When you check the [Designate from chart] box,
you can specify a zone range by dragging red lines
shown on the chart.
Bottom beam:
Not specified
Top beam: Not
specified
Desired beam
(in 1-beam increments)
4 Confirm zone To confirm the setting of the specified zone, execute
[Confirm Zone].
--
5 Designated beam
state
Select either Dark-ON or Light-ON. Dark-ON Dark-ON/Light-ON
6 Close Returns to Auxiliary Output/Lamp setting. - -