229
F3SG-SR
User’s Manual
Chapter4 Monitoring with SD Manager 3
Setting with SD Manager 3
E
* The error log information of the emitter is displayed only when the sensor is connected in the Wired Synchronization.
• Refer to 8-1-2. LOCKOUT State for more information on the error codes and descriptions.
• Refer to 2-26-4. Power-ON Time for more information on the accumulated power-on time.
• Error logs are only displayed for a sensor segment selected in the Target sensor section.
• Up to 50 past errors can be recorded. Up to last five logs are displayed without logging in.
• When the F3SG-SR is in a cascade connection, select a desired sensor segment from the [Target sensor]
button in the top right corner of the screen.
No. Function Description
1 Error Log Information
(Receiver)
Shows error logs including error codes, error descriptions and accumulated power-on time
at the time when errors occurred, with the most recent errors first for the receiver.
2 Error Log (Emitter) * Shows error logs including error codes, error descriptions and accumulated power-on time
at the time when errors occurred, with the most recent errors first for the emitter.
3 Show error descriptions Click an error to show details, cause and measures of the event.
4 Save maintenance
information
Saves error and warning logs, Intelligent Tap log, power-on time, accumulated power-on
time, load switching frequency and accumulated load switching frequency as a .csv file.