User’s Manual
Chapter5 Cascade Connection
Wiring and Installation
E
Properly connect an emitter to another emitter, and a receiver to another receiver, as shown below.
If caps and Cascading Cables are not connected properly, the F3SG-SR enters lockout (when power is turned ON).
Do not series-connect an emitter and receiver.
They will enter the LOCKOUT state.
Do not face different models of emitters and
receivers toward each other. They will enter
the LOCKOUT state or will be unable to detect
objects.
Secondary
sensor 1
(Emitter)
Secondary
sensor 1
(Emitter)
Secondary
sensor 1
(Receiver)
Secondary
sensor 1
(Receiver)
Primary
sensor
(Emitter)
Primary
sensor
(Emitter)
Primary
sensor
(Receiver)
Primary
sensor
(Receiver)
Secondary
sensor 1
(Emitter)
Secondary
sensor 1
(Receiver)
Primary
sensor
(Emitter)
Primary
sensor
(Receiver)

Table of Contents