10
Chapter1 LED Indicators on F3SG-SR
F3SG-SR
User’s Manual
Overview and Specifications
Receiver (F3SG-SR)
Location Indicator Name Color Illuminated Blinking
F3SG-
SRA
F3SG-
SRB
1 Scan code
Green Code A is selected
-XX
Orange Code B is selected
OFF
Automatic interference
prevention by wired
synchronization being
performed
2 Lockout Red
LOCKOUT state. The
indicator is illuminated in
the receiver of another
sensor segment than that
having a lockout error
(when in cascade
connection or between
the emitter and receiver
in the Wired
Synchronization)
LOCKOUT state. The indicator is
illuminated in the receiver of a sensor
segment having a lockout error
XX
3 ON/OFF
Green
Safety outputs are in ON
state
-XX
Red
Safety outputs are in
OFF state
LOCKOUT state due to Safety output
error, or error due to abnormal power
supply or noise
XX
4
Maintenance
Red
LOCKOUT state due to a
recoverable error (When
in cascade connection,
the indicator of only the
sensor segment having
the error is illuminated)
LOCKOUT state due to a
replacement-recommended error
(When in cascade connection, the
indicator of only the sensor segment
having the error blinks)
XX
Orange
Safety outputs are
instantaneously turned
OFF due to ambient light,
vibration or noise.
Or sequence error in
Muting, Pre-Reset or
PSDI
Intelligent Tap is in the LOCKOUT
state
XX
5
PNP/NPN
mode
Green
PNP is configured Polarity of PNP is changed to NPN, or
vice versa, during operation, and
internal circuit is defective
XX
OFF
NPN is configured
6
Configuration
Green
Fixed or Floating
Blanking, Reduced
Resolution, Warning Zone
or Slow mode of
Response Time
Adjustment is enabled.
Or after the Muting zone
is determined by the
Dynamic Muting function.
TEACH-IN mode, zone measurement
being performed by Dynamic Muting,
or LOCKOUT state due to Blanking
monitoring error, Configuration error
or Parameter error X X
7 Sequence Yellow
INTERLOCK state Sequence or sequence error in
Muting, Pre-Reset or PSDI (*1) or
Teach-in error
XX
CODE
C
or
ERR
E
or
OSSD
O
or
MAINT
M
or
PNP
P
or
CFG
F
or
SEQ
S
or

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron F3SG-SRB Series and is the answer not in the manual?

Omron F3SG-SRB Series Specifications

General IconGeneral
BrandOmron
ModelF3SG-SRB Series
CategorySecurity Sensors
LanguageEnglish

Related product manuals