Pulse output instructions
1216
Part IV Tool Instructions
PulseControl_Set
Defaults
Sets defaults for pulse output channel
To add an enable input and enable output to the instruction, select [With EN/ENO] from the
"Instructions" pane (LD, FBD or IL editor). To reuse an instruction select "Recently used" from the
context menu or press <Ctrl>+<Shift>+<v> in the programming window.
PLC types see page 1329
Variable Data type Function
iChannel INT Pulse output channel:
FP
: 0, 2
FP-X R: 0, 1
FP-X 16K C14T: 0, 1, 2
FP-X 32K C30T, C60T: 0, 1, 2, 3
FP0R: 0, 1, 2, 3
FP0: 0, 1
FP-e: 0, 1
Description
This instruction sets all bits of the pulse output control code (see page 1021) of the channel
specified by iChannel to 0. 0 is the default setting.
Data types
Example
In this example the function has been programmed in ladder diagram (LD) and structured text (ST).
The same POU header is used for all programming languages.
POU header
All input and output variables used for programming this function have been declared in the POU
header.
Body
LD
ST
When programming with structured text, enter the following:
if DF(bSetDefaults) then
PulseControl_SetDefaults(iChannel := iChannel);
end_if;