EasyManua.ls Logo

Panasonic FP Series

Panasonic FP Series
1345 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Arithmetic instructions
386
Part III FP Instructions
F57_BDEC
4-digit BCD decrement
15 . . 12 10 . . 8 7 . . 4 3 . . 0
d
0 1 0 0 0 0 1 1 0 0 1 0 0 0 1 0
16# BCD
15 . . 12 10 . . 8 7 . . 4 3 . . 0
d
0 1 0 0 0 0 1 1 0 0 1 0 0 0 0 1
16# BCD
4 3 2 2
4 3 2 1
Trigger: ON
Result value 4321 (BCD)
Bit
Bit
Example value 4322 (BCD)
This instruction also exists as a P instruction (for FP2/2SH, FP3/5, FP10/10SH PLC types), which
is only executed at the rising edge of the EN trigger. Select [Insert P instruction] from the
"Instructions" pane if you require a P instruction. To facilitate reuse, the instruction then appears
under "Recently used" in the pop-up menu. Press <Ctrl>+<Shift>+<v> within the programming
area to open the list of recently used elements.
PLC types
Availability of F57_BDEC (see page 1325)
Variable Data type Function
d WORD 16-bit area for BCD data to be decreased by 1
For Relay T/C Register Constant
d - WY WR WL SV EV DT LD FL -
No. IEC address Set If
R900B %MX0.900.11 for an instant the calculated result is 0.
R9009 %MX0.900.9 for an instant the result exceeds the range of 4-digit
BCD data (underflow).
Description
Subtracts "1" from the 4-digit BCD data specified by d if the trigger EN is in the ON-state. The
result is stored in d.
Data types
Operands
Error flags
Example
In this example, the same POU header is used for all programming languages. For an example
using IL (instruction list), please refer to the online help.
POU header
All input and output variables used for programming this function have been declared in the POU
header.

Table of Contents

Other manuals for Panasonic FP Series

Related product manuals