Basics
57
Example:
Value Conversion function Result
IPADDR_TO_STRING 004.003.002.001 16#01020304
IPADDR_TO_STRING_NO
_LEADING_ZEROS
4.3.2.1
NOTE
If you want an interpretation of the DWORD in direct order, use the conversion functions that
invoke the data type ETLANADDR.
1.4.5.8 ETLANADDR
The data type ETLANADDR only occurs in the following conversion functions:
ETLANADDR_TO_STRING (see page 234)
ETLANADDR_TO_STRING_NO_LEADIN
G_ZEROS (see page 235)
STRING_TO_ETLANA
DDR (see page 249)
STRING_TO_ETLANADDR_STEPSAVER
These conversi
on functions interpret variables of the type DWORD as strings in ETLANADDR format. This
format consists of four octal numbers (with or without leading zeros) seperated by periods in direct order, i.e. the
highest octal number in the ETLANADDR number will be the highest octal number in the string.
Example:
Value Conversion function Result
ETLANADDR_TO_STRING 001.002.003.004 16#01020304
ETLANADDR_TO_STRING_
NO_LEADING_ZEROS
1.2.3.4
NOTE
If you want an interpretation of the DWORD in inverse order, use the conversion functions
invoking the data type IPADDR.
1.4.5.9 ANY_IN_UNITS_OF_WORDS
Allowed are:
Data types INT, DINT, WORD, DWORD, REAL, STRING, TIME
Arrays with data types other than BOOL
All DUTs that contain elements with data types besides BOOL
Note:
These data types can lie in the following areas: WX, DWX, WY, DWY, WR, DWR, WL, DWL, SV,
DSV, EV, DEV, DT, DDT, LD, DLD, FL, DFL. For failure to make an assignment in the address field

Table of Contents

Other manuals for Panasonic FP Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Panasonic FP Series and is the answer not in the manual?

Panasonic FP Series Specifications

General IconGeneral
MountingDIN rail
TypePLC
Communication InterfaceRS-232, RS-485, Ethernet (depending on model)
Input Voltage100-240V AC or 24V DC (depending on model)
Output TypeRelay, Transistor
I/O PointsVaries by model
Operating Temperature0°C to 55°C
DimensionsVaries by model
WeightVaries by model

Related product manuals