Pulse output instructions
1225
Part IV Tool Instructions
PulseInfo_IsChannel
Enabled
Checks if pulse output channel is enabled
See also:
Pulse output tool instructions in the online help
Required system register settings
PLC types see page 1329
Variable Data type Function
iChannel INT Pulse output channel:
FP
: 0, 2
FP-X R: 0, 1
FP-X 16K C14T: 0, 1, 2
FP-X 32K C30T, C60T: 0, 1, 2, 3
FP0R: 0, 1, 2, 3
FP0: 0, 1
FP-e: 0, 1
Output variable BOOL TRUE if the pulse output channel specified by iChannel is
enabled
Description
This instruction returns TRUE if the pulse output channel specified by iChannel has been enabled
in the system registers and is supported by the selected PLC type.
Data types
Example
In this example the function has been programmed in ladder diagram (LD) and structured text (ST).
The same POU header is used for all programming languages.
POU header
All input and output variables used for programming this function have been declared in the POU
header.
Body
LD
ST
When programming with structured text, enter the following:
if (bPulseChannel_Check) then
bChannelEnabled := PulseInfo_IsChannelEnabled(iChannel := iChannel);
end_if;