Conversion instructions
221
Part II IEC Instructions
DINT_TO_STRING
DOUBLE INTEGER into STRING
Generates a result string in right-aligned decimal representation, filled with leading spaces up to
the predefined maximum number of characters.
To add an enable input and enable output to the instruction, select [With EN/ENO] from the
"Instructions" pane (LD, FBD or IL editor). To reuse an instruction select "Recently used" from the
context menu or press <Ctrl>+<Shift>+<v> in the programming window.
Function used String1
defined as
Result
STRING[2] '78'
STRING[4] '5678'
STRING[6] '345678'
STRING[8] '12345678'
STRING[10] ' -12345678'
STRING[12] ' -12345678'
String1:=DINT_TO_STRING(-12345678)
and so on...
PLC types
Availability of DINT_TO_STRING (see page 1319)
When using the data type STRING with small PLCs like FP-e or FP0,
make sure that the length of the result string is equal to or greater than
the length of the source string.
For further information refer to the online help: Upgrade Problems with
Data Type STRING
Data type I/O Function
DINT input input data type
STRING output conversion result
Description
The function DINT_TO_STRING converts a value of the data type DINT to a value of the data type
STRING.
Explanation
Data types
Example
In this example, the same POU header is used for all programming languages. For an example
using IL (instruction list), please refer to the online help.
POU header
In the POU header, input and output variables are declared that are used in the function.
The input variable input_value of the data type DINT is intialized by the value 12345678. The
output variable result_string is of the data type STRING[11]. It can store a maximum of 11
characters. Instead of using the variable input_value, you can enter a constant directly at the
function’s input contact in the body.

Table of Contents

Other manuals for Panasonic FP Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Panasonic FP Series and is the answer not in the manual?

Panasonic FP Series Specifications

General IconGeneral
MountingDIN rail
TypePLC
Communication InterfaceRS-232, RS-485, Ethernet (depending on model)
Input Voltage100-240V AC or 24V DC (depending on model)
Output TypeRelay, Transistor
I/O PointsVaries by model
Operating Temperature0°C to 55°C
DimensionsVaries by model
WeightVaries by model

Related product manuals