Conversion instructions
141
Part II IEC Instructions
REAL_TO_DWORD
REAL into DOUBLE WORD
To add an enable input and enable output to the instruction, select [With EN/ENO] from the
"Instructions" pane (LD, FBD or IL editor). To reuse an instruction select "Recently used" from the
context menu or press <Ctrl>+<Shift>+<v> in the programming window.
PLC types Availability of REAL_TO_DWORD (see page 1330)
Data type I/O Function
REAL Input input data type
DWORD Output conversion result
Description
REAL_TO_DWORD moves bitset information of a REAL variable to a DWORD variable. The same
functionality can be obtained using DWORD_OVERLAPPING_DUT.
Data types
Example
In this example the function has been programmed in ladder diagram (LD) and structured text (ST).
POU header
All input and output variables used for programming this function have been declared in the POU
header.
LD
ST
When programming with structured text, enter the following:
DWORD_value := REAL_TO_DWORD(REAL_value);

Table of Contents

Other manuals for Panasonic FP Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Panasonic FP Series and is the answer not in the manual?

Panasonic FP Series Specifications

General IconGeneral
MountingDIN rail
TypePLC
Communication InterfaceRS-232, RS-485, Ethernet (depending on model)
Input Voltage100-240V AC or 24V DC (depending on model)
Output TypeRelay, Transistor
I/O PointsVaries by model
Operating Temperature0°C to 55°C
DimensionsVaries by model
WeightVaries by model

Related product manuals