Pulse output instructions
1227
Part IV Tool Instructions
PulseInfo_IsElapsed
ValueReset
Checks if elapsed value is set to 0
See also:
Pulse output tool instructions in the online help
PulseInfo_ReadElapsedValue (see page 1233)
PulseCo
ntrol_ElapsedValueReset (see page 1206)
PulseCo
ntrol_ElapsedValueContinue (see page 1204)
PLC types see page 1329
Variable Data type Function
iChannel INT Pulse output channel:
FP
: 0, 2
FP-X R: 0, 1
FP-X 16K C14T: 0, 1, 2
FP-X 32K C30T, C60T: 0, 1, 2, 3
FP0R: 0, 1, 2, 3
FP0: 0, 1
FP-e: 0, 1
Output variable BOOL TRUE if the channel specified by iChannel has been reset
Description
This instruction returns TRUE if the elapsed value of the pulse output channel specified by
iChannel has been reset to 0.
Data types
Example
In this example the function has been programmed in ladder diagram (LD) and structured text (ST).
The same POU header is used for all programming languages.
POU header
All input and output variables used for programming this function have been declared in the POU
header.
Body
LD
ST
When programming with structured text, enter the following:
if (bIsElapsedValueReset) then
bElapsedValueReset := PulseInfo_IsElapsedValueReset(iChannel :=
iChannel);
end_if;