Pulse output instructions
1219
Part IV Tool Instructions
Pulse_TargetValue
MatchClear
Clears target value match control
See also:
Pulse output tool instructions in the online help
PulseInfo_IsTargetValueMatchActive (see page 1229)
PulseInfo_ReadTa
rgetValueMatchValue (see page 1235)
To add an enable inp
ut and enable output to the instruction, select [With EN/ENO] from the
"Instructions" pane (LD, FBD or IL editor). To reuse an instruction select "Recently used" from the
context menu or press <Ctrl>+<Shift>+<v> in the programming window.
PLC types see page 1335
Variable Data type Function
iChannel INT Pulse output channel:
FP
: 0, 2
FP-X R: 0, 1
FP-X 16K C14T: 0, 1, 2
FP-X 32K C30T, C60T: 0, 1, 2, 3
FP0R: 0, 1, 2, 3
FP0: 0, 1
FP-e: 0, 1
Description
This instruction clears the target value match control on the channel specified by iChannel.
Data types
Example
In this example the function has been programmed in ladder diagram (LD) and structured text (ST).
The same POU header is used for all programming languages.
POU header
All input and output variables used for programming this function have been declared in the POU
header.
Body
LD
ST
When programming with structured text, enter the following:
if DF(bClearTargetValueMatch) then
Pulse_TargetValueMatchClear(iChannel := iChannel);
end_if;