Arithmetic instructions
428
Part III FP Instructions
POU header
All input and output variables used for programming this function have been declared in the POU
header.
Body
When the variable Start is set to TRUE, the Arctangent of the real number entered for the variable
TangentofAngle is calculated and the result stored at the address assigned by the compiler to the
variable Angle (units are radians).
LD