Process control instructions
957
Part III FP Instructions
ST
When programming with structured text, enter the following:
if (bScale) then
SCALE_INT(iInput := iInput,
iInputLowerLimit := 50,
iInputUpperLimit := 1000,
iOutputLowerLimit := 40,
iOutputUpperLimit := 2000,
iOutput => iOutput);
end_if;